Thus, to avoid the above dangers while starting a DC motor, it is necessary to limit the starting current. For that purpose, starters are used to start a DC motor. There are various starters like, 3 point starter, 4 point starter, No load release coil starter, thyristor starter etc.
The main concept behind every DC motor starter is, adding external resistance to the armature winding at starting.
4 Point Starter
In four point starters, the hold on coil is connected directly across the supply line through a protective resistance R. when the armature touches stud no 1.the line current divides into three parts
i) Armature starting resistance and overload release.
ii) A variable resistance and shunt field winding.
iii) Holding coil and current limiting resistance.
The field gets directly connected to the supply, as the lever moves touching the brass arc. The no voltage coil (or Hold on coil) is connected with a current limiting resistance Rh. This arrangement ensures that any change of current in the shunt field does not affect the current through hold on coil at all. This means that electromagnet pull of the hold-on coil will always be sufficient so that the spring does not unnecessarily restore the lever to the off position. This starter is used where field current is to be adjusted by means of a field rheostat.
The basic difference between three point and four point starters is the manner in which the hold on coil is connected. The unnecessary tripping of starter can be stopped by connecting separately or parallel both magnetizing and field coil. They are connected in such a way that both should carry their individual current. Thus voltage drop in one coil will not affect the voltage in other coil.
Disadvantages of four coil starter:
The only limitation of the four point starter is that it does not provide high speed protection to the motor. If under running condition field gets opened; the field current reduces to zero. As there is some residual flux present and speed (N) is directly proportional to flux (ΓΈ) the motor will tries to run with dangerously high speed .this is called high speed action of motor. In three point starter as no volt coil is directly connected to across the supply; its current is maintained irrespective of the current through the field winding .hence it always maintain the handle in run position as long as supply is there .and thus it doesn’t protect the motor from field failure conditions which returns into high speeding of the motor
very good explaination
ReplyDeleteThree Phase Motor Starter Manufacturers